Specifications
Server Specifications
Table F-1: ProLiant ML310 Server Specifications
Dimensions
Height 42.0 cm (16.5 in)
Depth 48.5 cm (19.1 in)
Width 19.1 cm (7.5 in)
Approximate weight 18.18 kg (40 lb), depending on options
Input specifications
(per power supply)
U.S. International
Rated input voltage 100 VAC to 120 VAC 200 VAC to 240 VAC
Rated input frequency 50 Hz to 60 Hz 50 Hz to 60 Hz
Rated input current 6 A 3 A
Input power (Btu/hr) 1,560 Btu/hr 1,560 Btu/hr
Output specifications (per power supply)
Rated steady-state
power
300 W
Maximum peak power 400 W
Temperature range (see Note)
Operating 50°F to 95°F 10°C to 35°C
Shipping -40°F to 158°F -40°C to 70°C
Maximum wet bulb
temperature
82.4°F 28°C
Relative humidity (noncondensing)
Operating 10% to 90% 10% to 90%
Nonoperating 5% to 95% 5% to 95%
Note: All temperature ratings shown are for sea level. There is an altitude
derating of 1°C per 300 m to 3,000 m (1.8°F per 1,000 ft to 10,000 ft).
F-2 HP ProLiant ML310 Server Setup and Installation Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: m-appf.doc
Codename: Son of Beast Part Number: 274431-002 Last Saved On: 11/22/02 2:11 PM