Solution 1
Cause
The NVDIMM was previously installed in a that had Channel Interleaving enabled. The current has Channel
Interleaving disabled.
Action
Disable Channel Interleaving in System Utilities.
For more information, see the HPE 8GB NVDIMM User Guide on the Hewlett Packard Enterprise website.
Solution 2
Action
Sanitize all NVDIMMs on Processor X.
For more information, see the HPE 8GB NVDIMM User Guide on the Hewlett Packard Enterprise website.
386-NVDIMM Error – Processor X, DIMM Y
Symptom
386-NVDIMM Error – Processor X, DIMM Y. NVDIMM Metadata is corrupted. All NVDIMMs on Processor X
are disabled. Action: Sanitize all NVDIMMs on Processor X.
Cause
The data on the NVDIMM metadata that defines how the NVDIMM is used in the is corrupt, and the has
NVDIMM-N Memory Interleaving enabled.
Action
Sanitize all NVDIMMs on Processor X.
For more information, see the HPE 8GB NVDIMM User Guide on the Hewlett Packard Enterprise website.
387-NVDIMM Error – Processor X, DIMM Y
Symptom
387-NVDIMM Error – Processor X, DIMM Y. NVDIMM Metadata is corrupted. NVDIMM is disabled. Action:
Sanitize the NVDIMM.
Cause
The data on the NVDIMM metadata that defines how the NVDIMM is used in the is corrupt, and the has
NVDIMM-N Memory Interleaving disabled.
Action
Sanitize the NVDIMM.
386-NVDIMM Error – Processor X, DIMM Y 101