Action
Install a driver that supports virtual service. For more information, see "Keeping the system current" in the
HPE ProLiant Gen9 Troubleshooting Guide, Volume I on the Hewlett Packard Enterprise website.
1705-Slot X Drive Array
Symptom
1705-Slot # Drive Array – Please replace Cache Module Super-Cap. Caching will be enabled once Super-
Cap has been replaced and charged.
Cause
The HPE Smart Storage battery is degraded or has failed.
Action
1. Replace the HPE Smart Storage Battery.
For more information, see the maintenance and service guide on the Hewlett Packard Enterprise
website.
2. Charge the HPE Smart Storage Battery.
1706-The Extended BIOS Data Area in Server Memory has been Overwritten
Symptom
1706-The Extended BIOS Data Area in Server Memory has been Overwritten. Smart Array Interrupt 13h
BIOS Cannot Continue.
– System Halted
Cause
An application has overwritten memory reserved by the Smart Array controller.
Action
If this occurs when a particular application is loaded, check for an updated version of that application. For
more information, see "Software issues" in the HPE ProLiant Gen9 Troubleshooting Guide, Volume I on the
Hewlett Packard Enterprise website.
1707-Slot X Drive Array Controller
Symptom
1707-Slot X Drive Array Controller - Bootstrap NVRAM checksum invalid. Action: Re-flash Smart Array
controller. If error persists, replace controller.
Cause
The Bootstrap NVRAM on the specified Smart Array controller is corrupt or invalid.
1705-Slot X Drive Array 115