Configuration information indicates one or more hard drive(s) are located in drive bays that are
inaccessible when the memory module is detached.
Capacity Expansion operation(s) are pending but cannot continue because the Cache Module has been
detached.
ALL logical drive(s) have been disabled. To avoid data loss, upgrade controller or move the drives back to
the original controller. Run Array Configuration Utility to discard the current array and create new
configuration
Access to the following disk drive(s) has been disabled:
Select “F1” to continue disabling these drives until a new array configuration is created on them. To avoid data
loss, move these drives back to the original controller.
Select “F2” to reset configuration in these disk drives now.
Cause
The cache module was removed or is defective.
The drives were moved to a controller that does not have a cache module attached.
Action
1. Attach a cache module to this controller, or move the drives back to the original controller. If Capacity
Expansion operations are pending, be sure that the original cache module is attached.
2. If all logical drives have been disabled, upgrade the controller or move the drives back to the original
controller to avoid data loss.
3. Run HPE SSA to discard the current array and create a new configuration.
For more information, see the HPE Smart Storage Administrator User Guide on the Hewlett Packard
Enterprise website.
4. If access to specific drives has been disabled, do one of the following:
Press the F1 key to continue disabling the drives until a new array configuration has been created. To
avoid data loss, move the drives back to the original controller.
Press the F2 key to reset the configuration for the drives.
1748-Slot # Drive Array – Unsupported Cache Module Battery Attached
Symptom
1748-Slot # Drive Array – Unsupported Cache Module Battery Attached. Please install battery pack(s) with
the correct part number.
Cause
The current HPE Smart Storage Battery is not supported on this cache module.
Action
1. Use the part number to verify that the component is supported.
132 1748-Slot # Drive Array – Unsupported Cache Module Battery Attached