For a list of supported options, see the product QuickSpecs on the Hewlett Packard Enterprise website.
2. Install a supported HPE Smart Storage Battery.
For more information, see the user guide on the Hewlett Packard Enterprise website.
1749-Slot X Drive Array – Cache Module Flash Memory being erased
Symptom
1749-Slot X Drive Array – Cache Module Flash Memory being erased. Caching will be re-enabled when flash
memory erase has completed.
Cause
The cache module flash memory is being erased.
Action
No action is required.
1750-Fixed Disk 0 failed ID command
Symptom
1750-Fixed Disk 0 failed ID command.
Cause
A fixed drive error was detected.
Action
Run the server setup utility and correct the configuration. For more information, see "UEFI System Utilities" in
the HPE ProLiant Gen9 Troubleshooting Guide, Volume I on the Hewlett Packard Enterprise website.
1751-Fixed Disk 1 failed ID command
Symptom
1751-Fixed Disk 1 failed ID command.
Cause
A fixed drive error was detected.
Action
Run the server setup utility and correct the configuration. For more information, see "UEFI System Utilities" in
the HPE ProLiant Gen9 Troubleshooting Guide, Volume I on the Hewlett Packard Enterprise website.
1752-Slot X Drive Array – Controller not supported in this server model
Symptom
1752-Slot X Drive Array – Controller not supported in this server model.
1749-Slot X Drive Array – Cache Module Flash Memory being erased 133