c. If the issue persists, power down the and move the drives back to the original controller.
d. If the issue persists, contact Hewlett Packard Enterprise support.
Controller State: The array controller contains redundant connections to one or more
physical drives that are not supported in the current configuration
Symptom
Controller State: The array controller contains redundant connections to one or more physical drives that are
not supported in the current configuration. Please remove the redundant connection(s) or, if your controller
supports it, install the appropriate license key to enable the dual domain feature.
Cause
The array controller contains unsupported redundant connections.
Action
1. Do one of the following:
Remove the redundant connections.
Install a license key to enable the dual-domain feature.
Controller State: The array controller has a configuration that requires more physical
drives than are currently supported
Symptom
Controller State: The array controller has a configuration that requires more physical drives than are currently
supported. You may reconfigure the controller, but the existing configuration and data will be overwritten and
potentially lost.
Solution 1
Cause
The configuration requires more drives than are currently supported.
Action
1. If this message is observed after moving a configured array of drives from another controller, do the
following:
14 Controller State: The array controller contains redundant connections to
one or more physical drives that are not supported in the current configuration