1784-Slot X Drive Array – Drive Failure
Symptom
1784-Slot X Drive Array – Drive Failure. The following disk drive(s) should be replaced:
Port X Box Y Bay(s) Z
Cause
A cable is not installed correctly.
A drive is not installed correctly or has failed.
Action
1. Be sure all cables are connected properly and securely.
For more information, see "Resolving loose connections" in the HPE ProLiant Gen9 Troubleshooting
Guide, Volume I on the Hewlett Packard Enterprise website.
2. Be sure all drives are fully seated.
3. Determine which drive is defective using HPE SSA. Then, replace the defective cables, drive, or both.
For more information, see the HPE Smart Storage Administrator User Guide on the Hewlett Packard
Enterprise website. For removal and replacement procedures, see the maintenance and service guide on
the Hewlett Packard Enterprise website.
1785-Slot XX Not Configured
Symptom
1785-Slot XX Not Configured. SAS cable configuration is invalid. Action: See User’s Guide for supported
cabling guidelines.
Cause
Connections between the drives or controllers are missing or incorrect.
Action
Verify connections between the drives, backplanes, and controller. For more information, see the user guide
on the Hewlett Packard Enterprise website.
1786-Slot X Drive Array Recovery Needed
Symptom
1786-Slot X Drive Array Recovery Needed. The following drive(s) need Automatic Data Recovery (Rebuild):
Port x Box y Bay(s) z
Select F1 to continue with recovery of data to drive. Select F2 to continue without recovery of data to drive.
Cause
A failed or replacement drive has not yet been rebuilt.