DEFERRED_WRITE_ERROR - Drive with write cache enabled reported that it could
not complete a write command that it previously indicated was successful [lost
data].
MISSING_IN_SAVE_RIS - Could not write to reserved configuration sectors after
multiple retries.
WRONG_REPLACE - A hot-plug tape drive was plugged in as a replacement into a
drive bay that a hard disk was removed from.
GDP_VPD_INQUIRY_FAILED - Could not read drive serial number after multiple
retries.
GDP_MODE_SENSE_FAILED - Could not read certain mode pages after multiple
retries.
DRIVE_NOT_IN_48BIT_MODE - SATA drive is not supported in 48-bit LBA mode.
DRIVE_TYPE_MIX_IN_HOT_PLUG - Attempt to hot-add a SATA drive as a replacement
in a SAS-only volume, or vice versa.
DRIVE_TYPE_MIX_IN_LOAD_CFG - attempt to use a SATA drive as a replacement in a
SAS-only volume, or vice versa.
PROTOCOL_ADAPTER_FAILED - Protocol layer reports that the protocol hardware
has failed; may be a controller failure.
FAULTY_ID_BAY_EMPTY - Drive responds to SCSI ID, but the corresponding bay is
empty.
FAULTY_ID_BAY_OCCUPIED - Bay is occupied by a drive that does not respond to
the corresponding SCSI ID.
FAULTY_ID_INVALID_BAY - Drive responds to an ID that doesn’t have a valid
corresponding bay.
WRITE_RETRIES_FAILED - Unable to complete a write operation after several
retries.
QUEUE_FULL_ON_ZERO - Drive indicates that its queue is full when we have no
requests outstanding to the drive.
SMART_ERROR_REPORTED - Drive has reported a predictive-failure error when
controller is configured to automatically fail [instead of reporting imminent
failure of] drives that report this error.
PHY_RESET_FAILED - Phy reset request failed.
FR_CHKBLK_FAILED_WRITE - Drive failed write command while checking for media
errors.
FR_ATI_TEST_FAILED_WRITE - Drive failed write command while checking for
errors.
OFFLINE_ERASE - Drive is offline due to a Secure Erase operation.
OFFLINE_TOO_SMALL - Drive is offline because it’s a replacement drive that is
too small.