• OFFLINE_DRIVE_TYPE_MIX - Drive is offline because it is not the correct type
for this array [SATA vs SAS].
• OFFLINE_ERASE_COMPLETE - Drive is offline because a Secure Erase operation has
completed on it but it hasn’t been replaced yet.
Message ID: 24776
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting that the <drive type> physical hard drive
located in bay <bay number> is now online.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24777
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting inconsistent data that was previously
consistent.<additional information>The inconsistent data may be caused by a
power loss during write activity or by a drive returning corrupt data. The
inconsistent data is between block address <lba number 1> and block address <lba
number 2> of logical drive <logical drive number>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
<additional information> values:
• “The parity data does not match the data drives.”
• “”
Message ID: 24778
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting that surface analysis has repaired an
inconsistent stripe on logical drive <logical drive number> by overwriting the
statistically incorrect stripe on the physical drive found in bay <bay number>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24779
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting that surface analysis has repaired an
inconsistent stripe on logical drive <logical drive number> by updating the
parity data to match the data drive contents.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24780
Severity: Warning
218 HPE Smart Array errors