Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting inconsistent data that was previously
consistent.<additional information>The inconsistent data may be caused by a
power loss during write activity or by a drive returning corrupt data. The
inconsistent data is between block address <lba number 1> and block address <lba
number 2> of logical drive <logical drive number>. The physical drive containing
the inconsistent data can be found in bay <bay number> of the MSA chassis.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
<additional information> values:
The parity data does not match the data drives.
“”
Message ID: 24781
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan module <module number> was <inserted /
removed>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24782
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan module <fan module number> has failed.
The external Smart Array controller may attempt to shut down power and/or spin
down the installed disk drive(s).
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24783
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan module <fan module number> is reporting
a degraded condition.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24784
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan module <fan module number> is now
operational.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24785
Severity: Informational