Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that a previously failed storage enclosure
processor (SEP) is now responding and operational.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24786
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that a storage enclosure processor (SEP) has
failed.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24787
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that all storage enclosure processors (SEPs)
have failed and there is currently no environmental management and monitoring
available for this storage enclosure.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24788
Severity: Informational
Log message: Surface analysis parity/consistency initialization forced complete for
logical drive <logical drive number> on external Smart Array array controller
located in the MSA chassis labeled as <chassis label>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24789
Severity: Informational
Log message: External Smart Array controller located in the MSA chassis labeled as
<chassis label> has reported that <number of passes> surface analysis passes
have completed for logical drive <logical drive number>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24790
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis number> is reporting that the <drive type> physical drive located in
bay <bay number> is in a SMART trip state that indicates the drive has reached 0
percent usage left. Indicates that the drive has a S.M.A.R.T wear error and is
approaching the maximum usage limit for writes (wear out). The drive should be
replaced as soon as possible.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24791
220 HPE Smart Array errors