Action
Remove any memory boards not supported by the installed processor.
For more information, see the user guide on the Hewlett Packard Enterprise website.
333-HP RESTful API Error
Symptom
333-HP RESTful API Error – Unable to communicate with iLO FW. BIOS configuration resources may not be
up-to-date.
Cause
A file transfer to or from timed out, causing an error during the communication.
Action
1. Reset the iLO firmware.
For more information, see the user guide on the Hewlett Packard Enterprise website.
2. Reboot the .
3. If the issue persists, remove AC power to the .
334-HP RESTful API Error
Symptom
334-HP RESTful API Error – RESTful API GET request failed (HTTP Status Code = NNN). BIOS
configuration resources were not consumed.
Cause
The iLO RESTful API returned an HTTP Error Status (other than 200-Success, 204-No Content, 304-Not
Modified, or 401-Unauthorized) as a response to a GET request from the BIOS.
Action
Restore Manufacturing Defaults in RBSU.
For more information, see "UEFI System Utilities" in the HPE ProLiant Gen9 Troubleshooting Guide, Volume I
on the Hewlett Packard Enterprise website.
335-HP RESTful API Error
Symptom
335-HP RESTful API Error – RESTful API PUT request failed (HTTP Status Code = NNN). BIOS
configuration resources may not be up-to-date.
Cause
The iLO RESTful API returned an HTTP Error Status (other than 200-Success, 412-Precondition Failed, or
401-Unauthorized) as a response to a PUT request from the BIOS.