For more information, see "UEFI System Utilities" in the HPE ProLiant Gen9 Troubleshooting Guide, Volume I
on the Hewlett Packard Enterprise website.
340-NVDIMM Error – Backup Error
Symptom
Persistent data backup failed and data is not available. Action: Replace NVDIMM if error persists.
Cause
The last backup operation, copying data from NVDIMM-N DRAM to NVDIMM-N flash memory, did not
complete successfully after a power loss or a reset.
Action
1. Sanitize the NVDIMM.
For more information, see the HPE 8GB NVDIMM User Guide on the Hewlett Packard Enterprise
website.
2. If the error persists, replace the NVDIMM.
For more information, see the maintenance and service guide on the Hewlett Packard Enterprise
website.
341-NVDIMM Error – Restore Error
Symptom
341-NVDIMM Error – Restore Error - Processor X, DIMM Y. Persistent data restore failed and data is not
available.
Cause
The restore operation, copying data from NVDIMM-N flash memory to NVDIMM-N DRAM, did not
complete successfully.
The NVDIMM has failed.
Action
Replace the NVDIMM.
For more information, see the maintenance and service guide on the Hewlett Packard Enterprise website.
342-NVDIMM Error – Uncorrectable Memory Error
Symptom
342-NVDIMM Error – Uncorrectable Memory Error - Processor X, DIMM Y. This NVDIMM will not be available
to the operating system. Action: Replace the NVDIMM.
Cause
Backup data on the NVDIMM contains uncorrectable memory errors.
84 340-NVDIMM Error – Backup Error