4. Use a lint-free cloth to clean the ribbon motion sensor.
5. Inspect the following parts for wear, damage, or binds. Repair as needed.
v Printhead carriage
v Printhead mask (mounted on carriage between ribbon and platen)
v Ribbon mounting brackets
6. Ensure that the lift motor mounting screws are tight.
7. Ensure that the lift motor connector is connected to the printhead assembly.
8. Ensure there are no breaks in the ribbon lift motor cable.
E90ARB4
Printhead
Printhead
Cable
Ribbon Lift
Motor Screws
Ribbon Lift Motor
Connector
Figure 86. Original Motor.
(Viewed From Top)