Installation
1. The position of the wiring on the new ribbon lift motor is different form the positioning of the wiring on the
original motor. See Figure 138 on page 406 for correct motor positioning and routing of the wiring. Route the
cable around the platen side of the motor between the mounting post and the motor body.
2. Ensure the cable does not contact any moving parts.
3. Reinstall the ribbon lift motor screws.
4. Reinstall the ribbon, and close the cover.
Automatic Forms Thickness Adjust (AFTA) Assembly
Removal
1. Remove the printer covers. See “Printer Covers” on page 347.
2. Record the indicator setting.
3. Disconnect the AFTA motor connector from the logic board.
Note the location of the connector and the cable path as a guide for re-installation.
Note: If the motor is being removed only to access other parts, do not disconnect the connector.
Chapter 5. Removals and Adjustments 407