Table 11. MAP 0150: Power Supply (continued)
Questions/Actions Yes No
8. a. Power off (O) the printer.
b. Connect the operator panel cable connector.
c. Power on (|) the printer.
Does the power supply fan run OK?
Go to step 9 on page 82. Power off (O) the printer.
Install a new operator panel assembly.
See “Operator Panel” on page 355.
-or-
Install a new EMI filter assembly (used
only with Model A00 early-level logic
board). See “EMI Filter (Model A00
Early-Level Logic Board Only)” on
page 377.
-or-
Install a new operator panel cable
assembly.
Run T&D in automatic mode to verify
correct printer operation. For Model
A00, see “How To Run the Test and
Diagnostic (T&D) Programs” on
page 161. For Models 001, 002, or 003,
see “How To Run the Test and
Diagnostic (T&D) Programs” on
page 201.
Chapter 1. Diagnosing Problems