11: BINARY ARITHMETIC INSTRUCTIONS
11-10 OPENNET CONTROLLER USER’S MANUAL
ROOT (Root)
Valid Operands
For the valid operand number range, see page 6-2.
Since the ROOT instruction is executed in each scan while input is on, a pulse input from a SOTU or SOTD instruction
should be used as required.
Valid Data Types
When a word operand such as D (data register) or L (link register) is designated as the source or destination, 1 point (word
data type) is used.
Examples: ROOT
Operand Function I Q M R T C D L Constant Repeat
S1 (Source 1) Binary data ——————XX X —
D1 (Destination 1) Destination to store results —————— XX ——
W (word) I (integer) D (double word) L (long)
X ———
When input is on, the square root of operand designated by S1 is extracted and
is stored to the destination designated by D1.
Valid values are 0 to 65535. The square root is calculated to two decimals,
omitting the figures below the second place of decimals.
S1
→ D1
ROOT(W) S1
*****
D1
*****
D1
D20
D10 → D20
I0
ROOT(W) S1
D10
3
D11
2
D10
4
D12
9997
D14
9998
D15
173
D21
141
D20
200
D22
9998
D24
9998
D25
Before Execution After Execution
D1
D21
D11 → D21
I1
ROOT(W) S1
D11
D1
D22
D12 → D22
I2
ROOT(W) S1
D12
D1
D24
D14 → D24
I4
ROOT(W) S1
D14
D1
D25
D15 → D25
I5
ROOT(W) S1
D15
2 1.41=
9998 99.98=
9997 99.98=
4 2.00=
3 1.73=
55
D13
741
D23
D1
D23
D13 → D23
I3
ROOT(W) S1
D13
55 7.4161=