EasyManuals Logo

IDEC OpenNet series User Manual

IDEC OpenNet series
427 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #329 background imageLoading...
Page #329 background image
24: REMOTE I/O SYSTEM
24-8 OPENNET CONTROLLER USERS MANUAL
D8090
Node 10
Logical Device No. Bus Segment No. + Position
D8091 Length Code High byte stores 0 (Note)
D8092 ID Code High byte stores 0
D8093 Device Level High byte stores 0
D8094
Node 11
Logical Device No. Bus Segment No. + Position
D8095 Length Code High byte stores 0 (Note)
D8096 ID Code High byte stores 0
D8097 Device Level High byte stores 0
D8098
Node 12
Logical Device No. Bus Segment No. + Position
D8099 Length Code High byte stores 0 (Note)
D8100 ID Code High byte stores 0
D8101 Device Level High byte stores 0
D8102
Node 13
Logical Device No. Bus Segment No. + Position
D8103 Length Code High byte stores 0 (Note)
D8104 ID Code High byte stores 0
D8105 Device Level High byte stores 0
D8106
Node 14
Logical Device No. Bus Segment No. + Position
D8107 Length Code High byte stores 0 (Note)
D8108 ID Code High byte stores 0
D8109 Device Level High byte stores 0
D8110
Node 15
Logical Device No. Bus Segment No. + Position
D8111 Length Code High byte stores 0 (Note)
D8112 ID Code High byte stores 0
D8113 Device Level High byte stores 0
D8114
Node 16
Logical Device No. Bus Segment No. + Position
D8115 Length Code High byte stores 0 (Note)
D8116 ID Code High byte stores 0
D8117 Device Level High byte stores 0
D8118
Node 17
Logical Device No. Bus Segment No. + Position
D8119 Length Code High byte stores 0 (Note)
D8120 ID Code High byte stores 0
D8121 Device Level High byte stores 0
D8122
Node 18
Logical Device No. Bus Segment No. + Position
D8123 Length Code High byte stores 0 (Note)
D8124 ID Code High byte stores 0
D8125 Device Level High byte stores 0
D8126
Node 19
Logical Device No. Bus Segment No. + Position
D8127 Length Code High byte stores 0 (Note)
D8128 ID Code High byte stores 0
D8129 Device Level High byte stores 0
D8130
Node 20
Logical Device No. Bus Segment No. + Position
D8131 Length Code High byte stores 0 (Note)
D8132 ID Code High byte stores 0
D8133 Device Level High byte stores 0
Allocation No. Description Remarks
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC OpenNet series and is the answer not in the manual?

IDEC OpenNet series Specifications

General IconGeneral
BrandIDEC
ModelOpenNet series
CategoryController
LanguageEnglish

Related product manuals