EasyManua.ls Logo

II Morrow Inc. NMC 2001 - Page 333

II Morrow Inc. NMC 2001
367 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
On The Ground (continued)
Indication Problem
MSG light stays on
after power-up.
Displayed message is:
LORAN1
STATIONS
HAVE
LOW SNR
(continued)
Aircraft may be parked near
something interfering with the signal
(APU, hanger, high-voltage lines).
Action
Movethe aircraft. Thesystemusually
does not work inside a hanger.
Indication Problem
MSG light stays on
after power-up.
Displayed message is:
IN USE POSITION
SENSOR CANNOT
COMPUTE
LAT/LON
The In-Use position sensoris not able
to calculate a position
Action
Select a different position sensor.
Indication Problem
MSG light is on after
run-up. Displayed
Message is:
LORAN1[or 2]
EST POS ERROR
(EPE) IS 1.8NM
Noise generated from the aircraft
alternator or magneto.
Action
Contact II Morrow dealer or factory.