143
UHK-430/CCU-430 1710 VER2 (E)
6.2 CCU Menu Configuration and Contents
CCU SETTINGS and ADJUSTMENT
6
CONFIGURATION
Set the external connection etc..
[ETHERNET SETUP] [PGM NO.] [POWER CONTROL] etc.
Setting Item Initial setting Setting value Description, Remarks
ETHERNET SETUP
Set the ETHERNET
IP ADDRESS
192.168. 1.100 
SUBNET MASK
 
DEFAULT GATE WAY
xxx.xxx.xxx.xxx 
SPEED/DUPLEX
$8721(*27,$7,21
$8721(*27,$7,210+$/)
0)8//0+$/)0
FULL
SET
5(%227&$1&(/
5(%227&$1&(/5(%227
EXECUTE
PGM NO.
Sets the program number.
CAM PGM NO. SET
OFF OFF, 1 to 99 Sets the ID display number for the entire CCU front side.
FRONT ID DISPLAY
OFF OFF / ON Sets the ON/OFF of the display for the entire CCU front side.
POWER CONTROL
OCP CAM PWR CTRL
--- 212))/$67
Selects the operation mode based on the status of the OCP
camera power switch.
CAM CODE
--- 1250$/&87 2SWLRQE\UHJLRQ86$RQO\
SAFETY&H.PWR
--- 1250$/&87
FIBER SINGLE MODE
OFF OFF / ON Sets the fiber single mode.
ENGINEER SET FILE RENEW
8SGDWHVWKH(1*,1((56(7),/(
PASSWORD
**** Inputs the password for updating.
0123456789
FILE SELECT
(1*,1((5
(1*,1((5(1*,1((5
(1*,1((5
DATA RENEW MODE
PUSH SET --> RENEW
PASSWORD ENTRY
6HWVWKHSDVVZRUGIRUXSGDWLQJWKH(1*,1((56(7),/(
INPUT
**** ,QSXWWKHFXUUHQW3$66:25' The initial value is 0000.
RENEW
**** 1HZ3$66:25'
CONFIRM
**** Reconfirm
123456789
FIRMWARE UPDATE
Updates the firmware.
MAIN SOFT
6149Vxx.xx.xx
ALL UPDATE
6182Vxx.xx.xx
SUB SOFT
6139Vxx.xx.xx
HD VP FPGA2
6091Vxx.xx.xx Displays "---" when the optional module is not implemented.
HD VP FPGA3
6093Vxx.xx.xx Displays "---" when the optional module is not implemented.
TRX VP FPGA1
6089Vxx.xx.xx
TRX VP FPGA2
6090Vxx.xx.xx
TRX VP FPGA3
6093Vxx.xx.xx
RET PRC FPGA1
6102Vxx.xx.xx
RET PRC FPGA2
6103Vxx.xx.xx
PLS/AUX FPGA
9[[[[[ [
MPU FPGA
6117Vxx.xx.xx
12G OUT FAGA
6128Vxx.xx.xx Displays "---" when the optional module is not implemented.
USB DATA SAVE
Collects the log data.
LOG DATA
',$* ',$*6:&17/0(18$//
PUSH SET --> SAVE
OTHERS
PM TALLY SEL
< <&200 6HOHFWV<7$//<287RU&2007$//<287
REM OPT ALARM LEVEL
$77(1 $77(1:$51,1*1*
Sets the optical receiver level of the optical alarm on the
remote panel.
REAR FAN SPEED
)$67 )$67 0 ,''/( /2:
Sets the rotating speed of the fan motor on the back side of
CCU.