10-15
TIMER/COUNTER UNIT
Figure 10-14 and Figure 10-15 shows writing a new count. If the counter receives a gate-trigger
after writing a new count but before the end of the current half-cycle, the count is loaded on the
next CLKINn pulse and counting continues from the new count (Figure 10-14). Otherwise, the
new count is loaded at the end of the current half-cycle (Figure 10-15).
Figure 10-14. Mode 3 – Writing a New Count (With a Trigger)
Figure 10-15. Mode 3 – Writing a New Count (Without a Trigger)
????864286410
Writes to
Counter
n
CLKIN
n
GATE
n
OUT
n
Control
Word = 16H
Count
86
Count = 8
Count = 10
A2407-02
A2406-01
????42424286
Writes to
Counter
n
CLKIN
n
GATE
n
OUT
n
Control
Word = 16H
Count
42
Count = 4
Count = 8

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel 386 and is the answer not in the manual?

Intel 386 Specifications

General IconGeneral
Architecturex86
Clock Speed12 MHz to 40 MHz
Transistor Count275, 000
Data Bus Width32-bit
Address Bus Width32-bit
Instruction Setx86
Introduced1985
Maximum Memory4 GB
Operating ModesReal mode, Protected mode, Virtual 8086 mode
MMUYes
Voltage5V
ModelIntel 386
PackagePGA
Process1.5 μm to 1 μm

Related product manuals