Intel
®
Server Board S5500BC TPS Appendix B: Sensor Tables
Revision 1.8 Intel order number: E42249-009 131
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event /
Reading Type
Event Offset
Triggers
Contrib. To
System Status
Assert
/ De-
assert
Readabl
e
Value /
Offsets
Event
Data
Rearm
Stand-
by
06 Non-
Redundant:
degraded from
fully redundant.
Degraded
07 - Redundant
degraded from
non-redundant
Degraded
Power Supply 1 Status
(PS1 Status)
50h
Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
00 Presence
OK
As
and
De
Trig Offset
A
01 - Failure
Degraded
X
02 Predictive
Failure
Degraded
03 - A/C lost
Degraded
06
Configuration
error
OK
Power Supply 2 Status
(PS/2 Status)
51h
Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As
and
De
Trig Offset
A
01 - Failure
Degraded
X
02 Predictive
Failure
Degraded
03 - A/C lost
Degraded
06
Configuration
error
OK