EasyManuals Logo

Intel SC5650BCDP Technical Product Specification

Intel SC5650BCDP
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #145 background imageLoading...
Page #145 background image
Intel
®
Server Board S5500BC TPS Appendix B: Sensor Tables
Revision 1.8 Intel order number: E42249-009 131
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event /
Reading Type
Event Offset
Triggers
Contrib. To
System Status
Assert
/ De-
assert
Readabl
e
Value /
Offsets
Event
Data
Rearm
Stand-
by
06 Non-
Redundant:
degraded from
fully redundant.
Degraded
07 - Redundant
degraded from
non-redundant
Degraded
Power Supply 1 Status
(PS1 Status)
50h
Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
00 Presence
OK
As
and
De
Trig Offset
A
01 - Failure
Degraded
X
02 Predictive
Failure
Degraded
03 - A/C lost
Degraded
06
Configuration
error
OK
Power Supply 2 Status
(PS/2 Status)
51h
Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As
and
De
Trig Offset
A
01 - Failure
Degraded
X
02 Predictive
Failure
Degraded
03 - A/C lost
Degraded
06
Configuration
error
OK

Table of Contents

Other manuals for Intel SC5650BCDP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel SC5650BCDP and is the answer not in the manual?

Intel SC5650BCDP Specifications

General IconGeneral
BrandIntel
ModelSC5650BCDP
CategoryServer
LanguageEnglish

Related product manuals