Intel
®
RAID Software User’s Guide 183
226 Warning Bad block reassigned on %s at %lx to %lx
227 Info Controller Hot Plug detected
228 Warning Enclosure %s temperature sensor %d differential detected
229 Info Drive test cannot start. No qualifying drives found
230 Info Time duration provided by host is not sufficient for self check
231 Info Marked Missing for %s on drive group %d row %d
232 Info Replaced Missing as %s on drive group %d row %d
233 Info Enclosure %s Temperature %d returned to normal
234 Info Enclosure %s Firmware download in progress
235 Warning Enclosure %s Firmware download failed
236 Warning %s is not a certified drive
237 Info Dirty cache data discarded by user
238 Info Drives missing from configuration at boot
239 Info Virtual drives (VDs) missing drives and will go offline at boot: %s
240 Info VDs missing at boot: %s
241 Info Previous configuration completely missing at boot
242 Info Battery charge complete
243 Info Enclosure %s fan %d speed changed
244 Info Dedicated spare %s imported as global due to missing arrays
245 Info %s rebuild not possible as SAS/SATA is not supported in an array
246 Info
SEP %s has been rebooted as a part of enclosure firmware download.
SEP will be unavailable
until this process completes.
247 Info Inserted PD: %s Info: %s
248 Info Removed PD: %s Info: %s
249 Info VD %s is now OPTIMAL
250 Warning VD %s is now PARTIALLY DEGRADED
251 Critical VD %s is now DEGRADED
252 Fatal VD %s is now OFFLINE
253 Warning Battery requires reconditioning; please initiate a LEARN cycle
254 Warning VD %s disabled because RAID-5 is not supported by this RAID key
255 Warning VD %s disabled because RAID-6 is not supported by this controller
Number Type Description