34 ESim for the PC4 and PF8 Printer Programmer’s Reference Manual
Once a form has been retrieved, it can be used over and over
again until another form is retrieved. All variable input data and
counter values are stored in the volatile memory, which means it
is lost when the printer loses power. If prompts are enabled,
existing data and counter values are displayed on the screen after
the related prompt. Any input data can be overwritten at will.
Command Explanation
?
Call for variables in the same form
CR/LF to use existing data in V00
CR/LF to use existing data in V01
Sam
Substitute data in variable V02
200000
Substitute counter start value
P1,1
Print 1 copy of 1 label

Table of Contents

Other manuals for Intermec EasyCoder PC4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PC4 and is the answer not in the manual?

Intermec EasyCoder PC4 Specifications

General IconGeneral
Resolution203 dpi
Power Requirements100-240 VAC, 50-60 Hz
Print MethodDirect Thermal
Max Print Width4.09 inches (104 mm)
Max Print Speed4 inches per second
Max Print Length39 inches
Media TypeRoll-fed, die-cut, continuous, fanfold, tags, tickets
Media Width1.0 - 4.65 inches
Media Thickness0.06 mm (0.00236 in) to 0.18 mm (0.00708 in)
InterfaceRS-232
Memory4 MB Flash, 8 MB SDRAM
Operating Temperature5°C to 40°C (41°F to 104°F)
Storage Temperature-4°F to 140°F (-20°C to 60°C)
Humidity10 to 90% non-condensing