3─129
3.11.4 Overview of Stored Function Setting Data
The overview of stored function setting data is as follows:
• Factory-set data: Stored data that general operation cannot change
• Default data: Standard data of each function mode that users can change
• Data that can be called: Stored data that can be called by pressing the [FUNC] key
[Page 1] [1] Call Mode
• Calls the standard setting of the mode, and stores it for the function number.
[Page 1] [6] Save Present State
• The currently operating state can be stored for the function number.
• Use this function to store the state of good setting that will be frequently used.
[Page 5] [7] Save Default of Mode
• Stores the setting of the current function number, as the default setting of the mode.
[Page 5] [8] Initialization
• Changes the memory contents of the mode, which is used with the current function number, back to
the factory setting.
COAST
DEEPSEA
FISHNET
STORM
CALM
RAIN
BIRD
LONG
BUOY
USER1
USER2
COAST
DEEPSEA
FISHNET
STORM
CALM
RAIN
BIRD
LONG
BUOY
USER1
USER2
FUNC1
FUNC2
FUNC3
FUNC4
PRESENT
[5]-[8] [1]-[1]
[5]-[7]
[FUNC]
[1]-[7]
Function Setting
Factory-set data
Function Setting
Default data
Function Setting
Data that can be called
Current data