Loading...
130
15. ERROR CODE LIST
Error code Pictograph Description of error
How to recover
Place of recovery
E000
Contact of initialization of main shaft EEP-ROM of
MAIN p.c.b.
When data is not written in EEP-ROM or data is broken, data is
automatically initialized and the initialization is informed.
Turn OFF
the power.
E001
Contact of initialization of main EEP-ROM of MAIN p.c.b.
When data is not written in EEP-ROM or data is broken, data is
automatically initialized and the initialization is informed.
Turn OFF
the power.
E003
Main shaft motor encoder defectiveness
Angle counter of needle UP detection has exceeded the
value equivalent to 1.1 turns.
Angle counter of needle DOWN detection has exceeded
the value equivalent to 1.1 turns.
Turn OFF
the power.
E004
Main shaft motor needle DOWN detection defectiveness
Angle counter of needle UP detection has not exceeded the value
equivalent to 1.1 turns.
Angle counter of needle DOWN detection has exceeded the value
equivalent to 1.1 turns.
Turn OFF
the power.
E005
Main shaft motor needle UP detection defectiveness
Angle counter of needle UP detection has exceeded the
value equivalent to 1.1 turns.
Angle counter of needle DOWN detection has exceeded
the value equivalent to 1.1 turns.
Turn OFF
the power.
E006
Contact of initialization of machine head EEP-ROM of the
circuit board mounted on the machine head
When data is not written in EEP-ROM or data is broken, data is
automatically initialized and the initialization is informed.
Turn OFF
the power.
E007
Main shaft motor-lock
When large needle resistance sewing product is sewn
Turn OFF
the power.
E011
External media not inserted
External media is not inserted.
P o s s i b l e
to recover
by reset.
Pr e v i o u s
screen
E012
Read error
Data read from external media cannot be performed.
P o s s i b l e
to recover
by reset.
Pr e v i o u s
screen
E013
Write error
Data write from external media cannot be performed.
P o s s i b l e
to recover
by reset.
Pr e v i o u s
screen
E014
Write protect
External media is in the write prohibition state
P o s s i b l e
to recover
by reset.
Pr e v i o u s
screen

Table of Contents