1) Level 1
Memory switch data (level 1) are the motion data that the sewing machine has in common and the data
that operate on all sewing patterns in common.
14-2 Memory switch data list
No. Item
Setting range
Edit unit
Initial display
Reverse stitching at the sewing start selection
Select from among three kinds of without, single and double.
: Without : Single : Double
– – – – – – Without
Reverse stitching at the sewing end selection
Select from among three kinds of without, single and double.
: Without : Single : Double
– – – – – – Without
Number of stitches of reverse stitching
Number of stitches at the sewing start
and that at the sewing end are set.
0 to 19 1 stitch 5 stitches
Reverse stitching speed
Speed of the reverse stitching at the sewing
start and the sewing end is set.
200 to
3000
10sti/min 800sti/min
Needle position at the time of stop
Needle position at the time of temporary stop during sewing
is selected.
: DOWN : UP
– – – – – – DOWN
Number of stitches of soft start setting
Number of stitches of soft start at the
sewing start is set.
0 to 9
1 stitch 0 stitch
Soft start speed setting
Speed of soft start at the sewing start is
set.
200 to
2000
10sti/min 800sti/min
Condensation sewing selection
Select from among four kinds of without, start only, end only
and both start and end.
: Without : Start
: End : Both
– – – – – – Without
Number of stitches of condensation
Number of stitches of condensation sew-
ing is set.
0 to 9 1 stitch 0 stitch
Condensation speed setting
Speed of condensation sewing is set.
200 to
2000
10sti/min 800sti/min
Base tension in waiting state
Base tension in waiting state (except dur-
ing sewing) is set.
0 to 200 1 20