Power requirements
• Power consumpon at dierent temperatures when all ports are congured in 10-
Gbps speed:
25° C: 420 W (without MACSec), 430 W (with MACSec)
40° C: 430 W (without MACSec), 450 W (with MACSec)
55° C: 450 W (without MACSec), 480 W (with MACSec)
• Power consumpon at dierent temperatures when all ports are congured in 1-
Gbps speed:
25° C: 360 W (without MACSec), 370 W (with MACSec)
40° C: 370 W (without MACSec), 390 W (with MACSec)
55° C: 390 W (without MACSec), 420 W (with MACSec)
LEDs PWR LED
• Steady green—Line-card power is ok.
• Steady red—Line-card power-on has failed.
• O—Line card is not receiving power.
STS LED
• Steady green (blinking green when the beacon or the port locaon is on)—Line card is
online.
•
Blinking green—The line card is boong.
•
Steady red (blinking red when the beacon or the port locaon is on)—Line card is
faulty or an alarm has been raised.
•
O—Line card is disabled or oine.
Port LED
• O—Port does not have a transceiver module.
• Steady green (blinking green when the beacon or the port locaon is on)—Port link is
up with no alarms or failures.
• Steady amber (blinking amber when the beacon or the port locaon is on)—Port link
is down because the port is disabled through the CLI or the port encountered errors
such as loss of signal, local fault, or remote fault.
72