Table 11: Fan Tray LEDs on an MX10016 (continued)
DescriptionStateColorName
The left-most SFB behind the right fan tray
is online.
On steadilyGreenSFB 3 status
The beacon feature is enabled. This feature
is enabled using the request chassis
beacon command.
BlinkingGreen
An error has been detected in SFB 3.
Replace the SFB as soon as possible. The
SFB is located behind the right fan tray and
is the leftmost SFB in the grouping of 3.
To maintain proper airflow through the
chassis, leave the fan tray installed in the
chassis until you are ready to replace the
SFB.
BlinkingYellow
The SFB is offline.OffNone
The center SFB behind the right fan tray
is online.
On steadilyGreenSFB 4 status
The beacon feature is enabled. This feature
is enabled using the request chassis
beacon command.
BlinkingGreen
An error has been detected in SFB 4.
Replace the SFB as soon as possible. The
SFB is located behind the right fan tray and
is the middle SFB in the grouping of 3. To
maintain proper airflow through the
chassis, leave the fan tray installed in the
chassis until you are ready to replace the
SFB.
BlinkingYellow
The SFB is offline.OffNone