MULTICAL®603
KamstrupA/S∙Technicaldescription∙55122029_A1_GB_06.2017
15
PulseinputsAandB
InA6566andInB:6768viamodule
Electronicswitch Reedswitch
Pulseinput
680kpullupto3.6V 680kpullupto3.6V
PulseON
0.4Vfor30ms 0.4Vfor500ms
PulseOFF
2.5Vfor30ms 2.5V
for500ms
Pulsefrequency
3Hz 1Hz
Electricalisolation No No
Maxcablelength 25m 25m
Requirements to external
Leakagecurrentatfunctionopen1A
Updateofdisplay Followstheselectedintegrationinterval(from2to64s)
Pulseoutputs
CandD
OutC:1617andOutD:1819via
module
Pulseduration:
Pulsevalue
Whenpulseoutputsareusedfor
e.g.remotecountingofenergyand
volumewiththesameresolutionas
thedisplay
1
Heatmeter: OutC=CE+
OutD=CV
Coolingmeter: OutC=CE‐
OutD=CV
Heat/coolingmeter: OutC=CE+
OutD=CE‐
Selectable:
10ms,32msor
100ms
Pulsevalue
Whenpulseoutputsareusedas
pulsetransmitter/dividerfore.g.
regulationpurposes
Transmitter: OutC=V1
OutD=V2
4ms
Divider: OutC=V1/4

22ms

Communicationmodule TypeHC00321 TypeHC00311 TypeHC00311
Before20170501 After20170501
Pulseoutputtype Opencollector(OB) Opencollector(OB) OptoFET
Externalvoltage 5…30VDC 5…30VDC 5…48VDC/AC
Current 1…10mA 1…10mA 1…50mA
Residualstress
U
CE
≈1Vat10mA U
CE
≈1Vat10mA
R
ON
≤40
Electricalisolation 2kV 2kV 2kV
Maxcablelength 25m 25m 25m
1
Athighresolution,thepulseoutputswillbereducedby1:10whenselecting32msand100ms.Seeparagraph3.2.10
aboutPPcodes.