MULTICAL®603
KamstrupA/S∙Technicaldescription∙55122029_A1_GB_06.2017
33
Thebelowmentionedtableliststhetarifftypes,forwhichMULTICAL
603canbeconfiguredandshowsthetariff
typesavailableforeachmetertype.
EE=00Noactivetariff
Ifnotarifffunctionisrequired,youselectthesetupEE=00.
Thetarifffunctioncan,however,atalaterstagebeactivatedthroughr econfigurationvia METERTOOLHCW(se e
Technicaldescription5512
2096).
EE=11Powercontrolledtariff
Ifthecurrentpower(P)exceedsTL2butislowerthanorequaltoTL3,energyiscountedinTA2paralleltothemain
register.IfthecurrentpowerexceedsTL3butislowerthanorequaltoTL4,energyiscountedinTA3parallel
tothe
mainregister.IfthecurrentpowerexceedsTL4,energyiscountedinTA4paralleltothemainregister.
PTL2
Accumulationinmainregisteronly
TL4TL3TL2
TL3PTL2
AccumulationinTA2andmainregister
TL4PTL3
AccumulationinTA3andmainregister
PTL4
AccumulationinTA4andmainregister
Settingupdata,TL3mustbehigherthanTL2andTL4mustbehigherthanTL3.
Thepowercontrolledtariffise.g.usedasabasisfortheindividualheatconsumer’sconnectionfee.Furthermore,this
tarifftypecanprovidevaluablestatisticaldataiftheheatingstationconsidersnewconstructionactivities.
EE= Tarifftype Function
Heatmeter
Metertype2
Heat/coolingmeter
Metertype3
Heatmeter
Metertype4
Coolingmeter
Metertype5
Heat/coolingmeter
Metertype6
Volumemeter
Metertype7
00 Noactivetariff Nofunction
11 Powertariff
EnergyisaccumulatedinTA2,TA3andTA4onthebasisofthepower
limitsenteredinTL2,TL3andTL4

12 Flowtariff
EnergyisaccumulatedinTA2,TA3andTA4onthebasisofthe flow
limitsenteredinTL2,TL3andTL4

13 t1t2tariff
EnergyisaccumulatedinTA2,TA3andTA4onthebasisofthet
limitsenteredinTL2,TL3andTL4

14 Inlettemperaturetariff
EnergyisaccumulatedinTA2,TA3andTA4onthebasisofthet1
limitsenteredinTL2,TL3andTL4.

15 Outlettemperaturetariff
EnergyisaccumulatedinTA2,TA3andTA4onthebasisofthet2
limitsenteredinTL2,TL3andTL4.

19 Timec ontrolledtariff
TL2=StarttimeofTA2
TL3=StarttimeofTA3
TL4=StarttimeofTA4

20
Heat/coolingvolumetariff
(TL2,TL3andTL4arenotused)
Volume(V1)isdividedintoTA2forheat(t1t2)andTA3forcooling
(t1t2).Forheat/coolingmeters,metertypes3and6,theenergy
accumulation also depends onΘ
HC
(TA4 is not used in this tariff
type).

21 PQtariff
EnergyatPTL2issavedinTA2,andenergyatQTL3issavedinTA3


Table of Contents

Other manuals for Kamstrup MULTICAL 603

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kamstrup MULTICAL 603 and is the answer not in the manual?

Kamstrup MULTICAL 603 Specifications

General IconGeneral
Flow SensorUltrasonic
Battery LifeUp to 16 years
Power SupplyBattery
Communication OptionsM-Bus, Wireless M-Bus, Modbus, BACnet
DisplayLCD
ApplicationHeating and Cooling
Pressure RatingPN16
ApprovalMID
AccuracyClass 2
Ambient Temperature Range55°C
Housing MaterialBrass