Heartbeatandstatusindication
MULTICAL®603usesthethreesmalldisplaysegmentsinthelowerleftcornerofthedisplaytoindicatevariousstatus
scenarios. Each segment will, depending on whether it is static or flashes, provide information about the giv en
functionalityinthemeter.Thisisshowninthe
figurebelow:
①Heartbeatsegment
Flashes‐Thissegmentalwaysflashesasanindicationthatboththemeter
anddisplayareactive.
②SETUPandconfigsegment
Constantlylit‐Themeter’sconfiglogisfull,anditisthereforenolonger
possibletochangetheconfiguration.
Flashes‐Itispossible
toaccesstheSETUPloop.Thesegmentflashesaslong
asthemeterisintransportstateor4minutesafterthecalculatortopand
basehavebeenseparated.
Turnedoff‐ItisnotpossibletoaccesstheSETUPlooportoconfigurethe
meterviaMETERTOOLHCW.
③Opticalinterfacesegment
1
Constantlylit‐Themeter’sopticalinterfaceisdeactivated,andoptical
communicationisthusnotpossible.
Flashes‐Theopticalinterfaceistemporarilyactive,flashesfor4minutes
afterthecalculatortopandbasehavebeenseparated.Inthisperiodoftime,
itispossibletoactivatetheopticalinterfacepermanently.
Turned
off‐Theopticalinterfaceisactive,anditispossibletocommunicate
withthemeter.
1
TheopticalinterfacecanbedeactivatedandactivatedviatheopticalreadoutheadandMETERTOOLHCW(see
Technicaldescription5512‐2097).