EasyManua.ls Logo

Kamstrup MULTICAL 603 - Page 76

Kamstrup MULTICAL 603
155 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MULTICAL®603
76
KamstrupA/S∙Technicaldescription∙55122029_A1_GB_06.2017
Thetablebelowshowstheparametersthatcanbechangedvia theSETUPloop.Belowthetable,eachparameteris
explained.
SETUPloop Indexnum ber
indisplay
1 Customernumber(N
o
1) 3001
2 Customernumber(N
o
2) 3002
3 Date 3003
4 Time
1
3004
5 Yearlytargetdate1(MM.DD) 3005
6 Monthlytargetdate1(DD) 3006
7 Flowsensorposition:Inletoroutletflow(Acode ) 3007
8 Energyunit(Bcode)
(CanbesettokWh,MWh,GJandGcal)
3008
9 PrimaryaddressofinternalMBus(N
o
34) 3009
10 Primaryaddressofmoduleslot1(N
o
34) 3010
11 Primaryaddressofmoduleslot2(N
o
34) 3011
12 Averagingperiodofmin./maxPandQ 3012
13
Heat/coolingshift(
hc
)
2
(Onlyavailableinmetertype6)
3013
14 Temperaturesensoroffset(t
r0
)
3
3014
15 Radioon/off 3015
16 InputA1(presetregister) 3016
17 InputB1(presetregister) 3017
18 MeternumberofInputA1 3018
19 MeternumberofInputB1 3019
20 TL2 3020
21 TL3 3021
22 TL4 3022
23 Presettingt5 3023
24 EndSetup 3024
1
InadditiontoadjustingthetimeviatheSETUPloop,timeanddatecanalsobechangedviaMETERTOOLHCWand
themodules.
2
hc
canonlybechangedinmetersconfiguredasmetertype6.Inthismetertype,youcanbothchange
hc
anddisable
the function. If you attempt to access thismenu in meters configured as other meter types, the message “Off” is
displayed.
3
Thisfunctioncanhavebeendisabledviatheselectedcountrycode.