MULTICAL®603
76
KamstrupA/S∙Technicaldescription∙5512‐2029_A1_GB_06.2017
Thetablebelowshowstheparametersthatcanbechangedvia theSETUPloop.Belowthetable,eachparameteris
explained.
SETUPloop Indexnum ber
indisplay
1 Customernumber(N
o
1) 3‐001
2 Customernumber(N
o
2) 3‐002
3 Date 3‐003
4 Time
1
3‐004
5 Yearlytargetdate1(MM.DD) 3‐005
6 Monthlytargetdate1(DD) 3‐006
7 Flowsensorposition:Inletoroutletflow(A‐code ) 3‐007
8 Energyunit(B‐code)
(CanbesettokWh,MWh,GJandGcal)
3‐008
9 PrimaryaddressofinternalM‐Bus(N
o
34) 3‐009
10 Primaryaddressofmoduleslot1(N
o
34) 3‐010
11 Primaryaddressofmoduleslot2(N
o
34) 3‐011
12 Averagingperiodofmin./maxPandQ 3‐012
13
Heat/coolingshift(
hc
)
2
(Onlyavailableinmetertype6)
3‐013
14 Temperaturesensoroffset(t
r0
)
3
3‐014
15 Radioon/off 3‐015
16 InputA1(presetregister) 3‐016
17 InputB1(presetregister) 3‐017
18 MeternumberofInputA1 3‐018
19 MeternumberofInputB1 3‐019
20 TL2 3‐020
21 TL3 3‐021
22 TL4 3‐022
23 Pre‐settingt5 3‐023
24 EndSetup 3‐024
1
InadditiontoadjustingthetimeviatheSETUPloop,timeanddatecanalsobechangedviaMETERTOOLHCWand
themodules.
2
hc
canonlybechangedinmetersconfiguredasmetertype6.Inthismetertype,youcanbothchange
hc
anddisable
the function. If you attempt to access thismenu in meters configured as other meter types, the message “Off” is
displayed.
3
Thisfunctioncanhavebeendisabledviatheselectedcountrycode.