MULTICAL®603
82
KamstrupA/S∙Technicaldescription∙5512‐2029
A1_GB
06.2017
23.Pre‐settingt5
Thetemperaturevaluet5canbesetintheinterval0.01…185.00°CintheSETUPloop.Thisvalueisusedinconnection
withthe calculationofoutletenergy registers,i.e.registers A1(A‐,heatat adiscount)andA2(A+,heatwith an
addition).Readmore
aboutthiscalculationandfunctioninparagraph7.1.3.
24.EndSetup
Themenuitem“EndSetup”enablesthetechniciantolocktheaccesstotheSETUPloopintransportstateandthus
lockthemeteragainstfurtherconfiguration.Todoso,theusermustkeeptheprimarykeyactivatedfor5
seconds.
DuringthefivesecondstheframesaroundthereadingEndSetupwillcurrentlybecomeilluminatedinthemeter’s
display.Thisactioncanbeundonebyreleasingtheprimarykeybeforethewholeframehasbecomeilluminated,i.e.
beforethe5secondshavepassed.
“EndSetup”isanimportantfunctionwhenthe
meterisintransportstate,butwhenthemeterisinoperation,
“EndSetup”isjustoneofthreewaystoexittheSETUPloop.Seeparagraph6.3.