FETCh[:SCALar]:CURRent:MAXimum?
FETCh[:SCALar]:VOLTage:MAXimum?
FETCh[:SCALar]:POWer:MAXimum?
FETCh[:SCALar]:CURRent:MINimum?
FETCh[:SCALar]:VOLTage:MINimum?
FETCh[:SCALar]:POWer:MINimum?
Returns the maximum or minimum value. Values returned are either in amperes, volts, or watts.
Parameter Typical Return
(none) <MIN value> or <MAX value>
Returns the measured maximum current FETC:CURR:MAX?
Returns the measured maximum voltage FETC:VOLT:MAX?
Returns the measured minimum power FETC:POW:MIN?
l FETC:POW:MIN? and FETC:POW:MAX? are only available on units with firmware revisions
A.02.01.1256 and B.02.01.1256 and up. See Firmware Update.
FETCh:AHOur? [IGNORE_OVLD]
FETCh:WHOur? [IGNORE_OVLD]
FETCh:AHOur? Returns the accumulated amp-hours.
FETCh:WHOur? - Returns the accumulated watt-hours.
Refer to Amp-Hour and Watt-Hour Measurements for details.
If any measurement sample was overrange, the query returns SCPI Not a Number (9.91E37). If the
optional IGNORE_OVLD parameter is sent, the accumulated measurement will be returned even if
some samples were outside of the measurement range.
Parameter Typical Return
IGNORE_OVLD ignore overload measurements <amp-hours> or <watt-hours>
Returns the amp-hour measurement FETC:AHO?
FETCh:ARRay:CURRent[:DC]? [<start_index>, <points>]
FETCh:ARRay:VOLTage[:DC]? [<start_index>, <points>]
FETCh:ARRay:POWer[:DC]?[<start_index>, <points>]
Returns the instantaneous measurement. Values returned are either in amperes, volts, or watts.
Optional parameters specify a subset starting at <startindex> and of length <points>.
The return format depends on the settings of the FORMat:BORDer and FORMat[:DATA] commands.
When the data format is set to ASCII, returned values are comma separated. When the data format is
set to REAL, data is returned as single precision floating point values in definite length arbitrary block
response format.
Keysight N6900/N7900 Series Operating and Service Guide 228
6 SCPI Programming Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies N6900 Series and is the answer not in the manual?

Keysight Technologies N6900 Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelN6900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals