Parameters
66 Operating manual for INVEOR α | DOC01539818 - 0004 | 2017-01 | V2.0 EN
1.051 Run up time 1 Unit: s
Relationship
to parameter:
1.021
1.054
Parameter
manual:
S.xy
Transfer status:
2
min.:
0.1 Own value
(to be entered!)
max.: 1000
def.: 5
Run up time 1 is the time that the drive controller needs to accelerate from
0 Hz to the max. frequency.
The run up time can be increased as a result of certain circumstances, e.g. if
the drive controller is overloaded.
1.052 Deceleration time 2 Unit: s
Relationship
to parameter:
1.021
1.054
Parameter
manual:
S.xy
Transfer status:
2
min.: 0.1 Own value
(to be entered!)
max.: 1000
def.: 10
Deceleration time 2 is the time that the drive controller needs to brake to 0 Hz
from the max. frequency (1.021).
If the set deceleration time cannot be reached, the fastest possible
deceleration time is implemented.
1.053 Run up time 2 Unit: s
Relationship
to parameter:
1.021
1.054
Parameter
manual:
S.xy
Transfer status:
2
min.: 0.1 Own value
(to be entered!)
max.: 1000
def.: 10
Run up time 2 is the time that the drive controller needs to accelerate from
0 Hz to the max. frequency.
The acceleration time can be increased as a result of certain circumstances,
e.g. if the drive controller is overloaded.