Parameters
70 Operating manual for INVEOR α | DOC01539818 - 0004 | 2017-01 | V2.0 EN
Relationship
to parameter:
1.131
Parameter
manual:
P. xy
Transfer status:
2
min.:
0 Own value
(to be entered!)
max.: 8
def.: 1
Selection of behaviour in response to enabling software (parameter 1.131).
No effect if autostart was selected.
0 = immediate start with high signal at start input of control enable
1 = start only with rising flank at start input of control enable
2 = digital input 1 (function active with high signal)
3 = digital input 2 (function active with high signal)
6 = INVEOR soft PLC
7 = analogue input 1 (must be selected in parameter 4.030)
(V 03.70 and higher)
Relationship
to parameter:
1.131
4.030
4.050
Parameter
manual:
P. xy
Transfer status:
2
min.:
0 Own value
(to be entered!)
max.: 16
def.: 0
Selection of direction of rotation specification
0 = dependent on target value (depending on the plus or minus sign of the
target value:
positive: forwards; negative: backwards)
1 = forwards only (no change in direction of rotation possible)
2 = backwards only (no change in direction of rotation possible)
3 = digital input 1 (0 V = forwards, 24 V = backwards)
4 = digital input 2 (0 V = forwards, 24 V = backwards)
7 = INVEOR soft PLC
8 = analogue input 1 (must be selected in parameter 4.030)
10 = foil keypad key for reversing direction of rotation
(only when motor is running)
11 = foil keypad key 1 forwards / 2 backwards (reversal always possible)
12 = foil keypad key 1 forwards / 2 backwards (reversal only possible when
motor stationary)
13 = virtual output (4.230) (V 03.70 and higher)
14 = foil keypad key for reversing direction of rotation (only in operational
status) storing
(V 03.70 and higher)
15 = foil keypad key I + key II storing (V 03.70 and higher)
16 = foil keypad key I + II (only if motor is stationary) storing
(V 03.70 and higher)