Parameters
82 Operating manual for INVEOR α | DOC01539818 - 0004 | 2017-01 | V2.0 EN
4.033 Al1 physical unit Unit:
Relationship
to parameter:
4.034
4.035
Parameter manual:
P. xy
Transfer status:
2
min.:
0 Own value
(to be entered!)
max.: 10
def.: 0
Selection of different physical values to be displayed.
0
1
2
3
4
5
6
7
8
9
10
=
=
=
=
=
=
=
=
=
=
=
%
bar
mbar
psi
Pa
m³/h
l/min
° C
° F
m
mm
4.034 Al1 physical minimum Unit:
Relationship
to parameter:
4.033
4.035
Parameter
manual:
P. xy
Transfer status:
2
min.: - 10000 Own value
(to be entered!)
max.: + 10000
def.: 0
Selection of the lower limit of a physical value to be displayed.
4.035 Al1 physical maximum Unit:
Relationship
to parameter:
4.033
4.034
Parameter
manual:
P. xy
Transfer status:
2
min.: - 10000 Own value
(to be entered!)
max.:+ 10000
def.: 100
Selection of the upper limit of a physical value to be displayed.