Multiplexing 377
Cummins Engine Parameters
The following table contains the engine programming parameters specific to the EXPERT™ units.
Enter those parameters into Cummins engine ECUs. For more information, call LabriePlus.
Table 8 Output
Wire # Description State
130 PTO enable output Active when the PTO switch is ON and when all engine
and vehicle speed criteria are respected (+12V signal).
See Programmed Parameters on page 375.
145 Neutral signal output Active when the transmission is in neutral. This signal
(ground signal) is used to allow fast idle engagement. For
more details, refer to the electrical schematic provided
with the vehicle.
Table 9 Cummins engine parameters
Menu: Features &
Parameters
Parameter Name Value
Adjustable low idle
speed
Low idle speed adjustment switch
---------------------------------------------------------------
Low idle speed
Disable
--------------------
700 RPM
Switched maximum
engine operating speed
Switched maximum engine operating speed
---------------------------------------------------------------
Maximum operating speed switch setup
---------------------------------------------------------------
Maximum switched engine speed
Enable
--------------------
Active closed
--------------------
900 RPM