General Maintenance 83
Figure 3-92
Flashing light removed
4. Remove all packer roller assemblies from the follower panels (See Rollers on page 190).
5. Fold the follower panels over the packer.
6. Weld the follower panels to the packer.
7. Attach the packer to a lifting device (fork lift, etc.) and lift it out of the hopper.
NEXT: INSTALLING NEW PACKER: See “A. Installing New Packer - Standard Units W/
Loading Arm” on page 89.
B. Removing Packer Panel - Standard Units W/O Loading Arm
Once the packer has been prepared, accessed and disconnected, you can remove it from the hopper.
To do so:
1. Remove both side panels (one on each side of the hopper).
Figure 3-93
Side panel
Warning!
Use an appropriate lifting device to lift the packer out of the hopper. Failure to do so may
result in serious injury or death or damage to the equipment.