Procedure
Step 1. Touch the static-protective package that contains the new part to any unpainted surface on the
outside of the server. Then, take the new part out of the package and place it on a static-protective
surface.
Step 2. Connect cables to the drive backplane. See
Chapter 6 “Internal cable routing” on page 271.
Step 3. Install the drive backplane into the rear drive cage.
Figure 207. Installing the 4 x 3.5-inch rear drive backplane
a. Align the bottom of the backplane with the studs at the bottom of the drive cage and lower
the backplane into the drive cage.
b.
Push the top of the backplane so that the holes in the backplane pass through the pins on
the drive cage, and the release latches secure the backplane in place.
Step 4. Install the rear drive cage.
Chapter 5. Hardware replacement procedures 235