Mains connecon
Inverter I55AE125A
I55AE137A
I55AE175A
I55AE211A
Connecon X100
Connecon type pluggable screw terminal
Min. cable cross-secon mm² 1
Min. cable cross-secon AWG 18
Max. cable cross-secon mm² 2.5 6
Max. cable cross-secon AWG 12 10
Stripping length mm 8
Stripping length inch 0.32
Tightening torque Nm 0.5 0.7
Tightening torque lb-in 4.4 6.2
Required tool 0.5 x 3.0 0.6 x 3.5
PE connecon
Inverter I55AE125A
I55AE137A
I55AE175A
I55AE211A
Connecon PE
Connecon type PE screw
Min. cable cross-secon mm² 1.5
Min. cable cross-secon AWG 14
Max. cable cross-secon mm² 6
Max. cable cross-secon AWG 10
Stripping length mm 10
Stripping length inch 0.39
Tightening torque Nm 2
Tightening torque lb-in 18
Required tool TORX TX20
Motor connecon
Inverter I55AE125A
I55AE137A
I55AE175A
I55AE211A
Connecon X105
Connecon type pluggable screw terminal
Min. cable cross-secon mm² 1
Min. cable cross-secon AWG 18
Max. cable cross-secon mm² 2.5
Max. cable cross-secon AWG 12
Stripping length mm 8
Stripping length inch 0.32
Tightening torque Nm 0.5
Tightening torque lb-in 4.4
Required tool 0.5 x 3.0
Electrical installaon
Mains connecon
1-phase mains connecon 120 V
31