Parameter Name / value range / [default seng] Info
0x2380
(P508.00)
PROFINET communicaon
(PROFINET comm.)
•
From version 02.00
Restart / stop communicaon
•
When the device command has been executed successfully, the value
0 is shown.
0 No acon/no error Only status feedback
1 Restart with current values Restart communicaon with the current values.
2 Restart with default values Restart communicaon with the standard values of the PROFINET
parameters (0x2381:001 ... 0x2381:009).
5 Stop network communicaon Stop communicaon
10 In process Only status feedback
11 Acon cancelled
12 Fault
0x2381:001
(P510.01)
PROFINET sengs: IP address
(PROFINET se.: IP address)
0 ... [0] ... 4294967295
•
From version 02.00
Set IP address
•
The change of this parameter becomes only eecve aer a restart.
0x2381:002
(P510.02)
PROFINET sengs: Subnet
(PROFINET se.: Subnet)
0 ... [0] ... 4294967295
•
From version 02.00
Set subnet mask
•
The change of this parameter becomes only eecve aer a restart.
0x2381:003
(P510.03)
PROFINET sengs: Gateway
(PROFINET se.: Gateway)
0 ... [0] ... 4294967295
•
From version 02.00
Set gateway address
•
The gateway address is valid if the network address of the IP address
is idencal to the gateway address. In this case, no gateway funcon-
ality is used.
•
DHCP is not supported.
•
The change of this parameter becomes only eecve aer a restart.
0x2381:004
(P510.04)
PROFINET sengs: Staon name
(PROFINET se.: Staon name)
•
From version 02.00
Set staon name
•
The change of this parameter becomes only eecve aer a restart.
0x2381:005 PROFINET sengs: I&M1 System designaon
•
From version 02.00
Input/output of the I&M1 system designaon
•
The default seng is an empty string.
0x2381:006 PROFINET sengs: I&M1 Installaon site
•
From version 02.00
Input/output of the I&M1 locaon idencaon code
•
The default seng is an empty string.
0x2381:007 PROFINET sengs: I&M2 Installaon date
•
From version 02.00
Input/output of the I&M1 date of installaon
•
The default seng is an empty string.
0x2381:008 PROFINET sengs: I&M3 addional informaon
•
From version 02.00
Input/output of the I&M1 addional informaon
•
The default seng is an empty string.
0x2381:009 PROFINET sengs: I&M4 signature code
•
From version 02.00
Input/output of the I&M1 signature
•
The default seng is an empty string.
Conguring the network
PROFINET
Basic sengs
367