EasyManua.ls Logo

Lenze i55AE155F

Lenze i55AE155F
702 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Name / value range / [default seng] Info
0x2BA1:001
(P718.01)
Flying restart circuit: Current
(Flying restart: Current)
0 ... [30] ... 100 %
The current set here is injected into the motor during the ying restart
process for the idencaon of the rotang eld frequency.
100 % ≡ Motor rated current 0x6075 (P323.00)
Reducing the current causes a reducon of the motor torque during
the ying restart process. A short-me starng acon or reversing of
the motor is prevented with low ying restart currents.
If the current is set too low, the rotang eld frequency cannot be
idened correctly.
If the current is increased, this improves the robustness of the ying
restart circuit.
In case of high mass ineras and high speeds, the ying restart circuit
may cause an overvoltage in the DC bus if no brake resistor is connec-
ted. In this case, the current must be reduced.
0x2BA1:002
(P718.02)
Flying restart circuit: Start frequency
(Flying restart: Start frequency)
-599.0 ... [20.0] ... 599.0 Hz
The frequency set here denes the starng point for the ying restart
process.
The search starts in posive direcon.
The default seng is adjusted to standard asynchronous motors.
In case of systems with a known search speed (e.g. torque-controlled
drive systems that are to synchronise to a dened speed), the start
frequency can be adapted for reducing the ying restart me.
0x2BA1:008
(P718.08)
Flying restart circuit: Flying restart frequency
(Flying restart: Fl.res.frequency)
Read only: x.x Hz
Display of the found frequency at which the motor has been successfully
restarted on the y.
Addional funcons
Flying restart circuit
482

Table of Contents

Related product manuals