Parameter Name / value range / [default seng] Info
0x2C49:002
(P711.02)
Posion counter: Reset mode
(Posion counter: Reset mode)
From version 03.00
Selecon if the manual reset of the posion counter is to be eected
edge-controlled or status-controlled.
0 Reset by rising edge
1 Reset by signal state true
0x2C49:003
(P711.03)
Posion counter: Actual posion
(Posion counter: Actual posion)
Read only
From version 03.00
Mappable parameter for providing the current counter content (actual
posion) via network.
Scaling (applies to every measuring method or encoder resoluon):
Upper 16 bits: Counted revoluons (0 ... 65535, overow possible)
Lower 16 bits: Current posion within the revoluon (0 ... 65535)
Addional funcons
Process data
Posion counter
494