29573 0x7385 Feedback system: speed limitaon Keypad display: F.fdb spd limit
Cause Error type/response Remedy
The feedback system exceeds the maximum
permissible frequency range of the digital
inputs.
Warning Check feedback system.
Related topics
4Encoder monitoring ^ 498
30336 0x7680 Memory module is full Keypad display: EPM full
Cause Error type/response Remedy
The memory module contains too many param-
eter sengs.
Warning
The parameter sengs were not saved in the
memory module.
Execute "Save user data" 0x2022:003 (P700.03)
device command again. This reinialises the
user memory with the current parameter set-
tings. In this way, parameter sengs that are no
longer required are automacally deleted.
30337 0x7681 No memory module Keypad display: EPM not present
Cause Error type/response Remedy
The inverter memory module was removed. Fault
The default seng stored in the inverter
rmware has been loaded.
The error cannot be reset by the user.
1.
Switch o inverter.
2.
Plug the memory module into the inverter.
3.
Switch the inverter on again.
Note: The memory module cannot be replaced
during ongoing
operaon!
30338 0x7682 Memory module: invalid user data Keypad display: EPM invalid data
Cause Error type/response Remedy
The user parameter sengs in the memory
module are invalid.
Fault
The inverter is inhibited immediately. The
motor becomes torqueless (coasts).
The user parameter sengs are lost.
The default sengs were automacally loa-
ded.
1.
Execute user parameter sengs again.
2.
Execute device command "Save user data"
0x2022:003 (P700.03).
30340 0x7684 Data not completely saved before switch-o Keypad display: Save incomplete
Cause Error type/response Remedy
Saving of the parameter sengs was interrup-
ted by an unexpected disconnecon.
Warning
The user parameter sengs were not fully
saved.
At the next switch-on, the data stored are
copied to the user memory.
1.
Check user parameter sengs. (The loaded
backup is an older version.)
2.
If required, repeat the changes made last.
3.
Execute device command "Save user data"
0x2022:003 (P700.03).
30342 0x7686 Internal communicaon error Keypad display: Int. Comm.Err.
Cause Error type/response Remedy
Communicaon between the power unit and
the control unit is faulty.
Fault
The inverter is inhibited immediately. The
motor becomes torqueless (coasts).
1.
Switch o inverter.
2.
Install control unit correctly on power unit.
3.
Switch the inverter on again.
Appendix