Diagnostic Information 2-93
5055-01X
Toner adheres to the back of the
page.
Remove the fuser oil roll and wipe it with
a dry, lint-free cloth, and clean the
transfer belt. If there still is a problem, go
to “Periodic Dirt” on page 2-97.
Quality of printed transparencies
is inadequate.
Be sure you’re using the recommended
Lexmark transparencies.
Be sure you have selected the correct
paper weight setting for the media you
are using.
When printing transparencies, always set
the Paper Type to Transparency.
Avoid getting fingerprints on
transparencies before printing.
Print on the page is skewed. Be sure the width guides in the paper tray
or the multipurpose feeder fit snugly
against the media you loaded.
Be sure the paper you load fits under the
two corner tabs at the front of the tray.
Be sure charge roll or belt is seated
properly.
A white gap is noticeable
between color fills, due to poor
color registration.
Be sure all four corners of the printer are
resting on a steady flat surface.
Turn the printer off and back on. The
printer calibrates the print head timing,
which may improve registration. Be sure
that Auto Registration, in diagnostic
mode, is On.
Problem Action
L