Error code Description Action
242.26 Paper fed from tray 2 was picked but it never
arrived at the sensor (tray 2 trailing edge).
See
“Sensor (tray [x] pass-through): Tray [x]
failed to pick service check” on page 141.
242.27 Paper fed from tray 2 never cleared the sensor
(tray 2 trailing edge).
See
“Sensors (tray [x] trailing edge and
passthrough): Paper failed to clear service
check” on page 143.
242.28 Paper fed from tray 2 was detected later than
expected at the sensor (tray 2 pass-through) or at
the sensor (tray 2 trailing edge).
See
“Sensors (tray [x] trailing edge and
pass-through): Paper arrived too late
service check” on page 145.
242.31 Paper fed from tray 3 remains detected at the
sensor (tray 2 passthrough) or at the sensor (tray
2 trailing edge) after the printer is turned on.
See
“Sensors (tray [x] trailing edge and
pass-through) static jam service check” on
page 129.
242.32 Paper fed from tray 3 was detected earlier than
expected at the sensor (tray 2 pass-through) or at
the sensor (tray 2 trailing edge).
See
“Sensors (tray [x] trailing edge and
passthrough): Paper arrived too early
service check” on page 130.
242.33 Paper fed from tray 3 never arrived at the sensor
(tray 2 pass-through).
See
“Sensor (tray 2 pass-through): Paper
failed to arrive service check” on page
132.
242.34 Paper fed from tray 3 cleared the sensor (tray 2
pass-through) or the sensor (tray 2 trailing edge)
earlier than expected.
See
“Sensors (tray [x] trailing edge and
pass-through): Paper cleared too early
service check” on page 137.
242.35 Paper fed from tray 3 cleared the sensor (tray 2
pass-through) or the sensor (tray 2 trailing edge)
later than expected.
See
“Sensors (tray [x] trailing edge and
pass-through): Paper cleared too late
service check” on page 138.
242.37 Paper fed from tray 3 never cleared the sensor
(tray 2 trailing edge).
See
“Sensors (tray [x] trailing edge and
passthrough): Paper failed to clear service
check” on page 143.
242.38 Paper fed from tray 3 was detected later than
expected at the sensor (tray 2 pass-through) or at
the sensor (tray 2 trailing edge).
See
“Sensors (tray [x] trailing edge and
pass-through): Paper arrived too late
service check” on page 145.
242.41 Paper fed from tray 4 remains detected at the
sensor (tray 2 passthrough) or at the sensor (tray
2 trailing edge) after the printer is turned on.
See
“Sensors (tray [x] trailing edge and
pass-through) static jam service check” on
page 129.
242.42 Paper fed from tray 4 was detected earlier than
expected at the sensor (tray 2 pass-through) or at
the sensor (tray 2 trailing edge).
See
“Sensors (tray [x] trailing edge and
passthrough): Paper arrived too early
service check” on page 130.
242.43 Paper fed from tray 4 never arrived at the sensor
(tray 2 pass-through).
See
“Sensor (tray 2 pass-through): Paper
failed to arrive service check” on page
132.
242.44 Paper fed from tray 4 cleared the sensor (tray 2
pass-through) or the sensor (tray 2 trailing edge)
earlier than expected.
See
“Sensors (tray [x] trailing edge and
pass-through): Paper cleared too early
service check” on page 137.
242.45 Paper fed from tray 4 cleared the sensor (tray 2
pass-through) or the sensor (tray 2 trailing edge)
later than expected.
See
“Sensors (tray [x] trailing edge and
pass-through): Paper cleared too late
service check” on page 138.
5028
Diagnostic information
125

Table of Contents

Other manuals for Lexmark CS725R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lexmark CS725R and is the answer not in the manual?

Lexmark CS725R Specifications

General IconGeneral
BrandLexmark
ModelCS725R
CategoryPrinter
LanguageEnglish

Related product manuals