Error code Description Action
172.82 The LVPS fuser fan peed did not ramp up to the
required level.
See
“LVPS fuser fan service check” on
page 199.
172.83 The LVPS fuser fan stalled.
172.84 The LVPS fuser fan ran too slow.
172.85 The LVPS fuser fan ran too fast.
Lower paper path sensors service check
Action Yes No
Step 1
Check the error that appeared.
Is the error 100.41?
Go to step 3. Go to step 2.
Step 2
Check the error that appeared.
Is the error 100.44?
Go to step 10. Go to step 3.
Step 3
Check the cable on the JPKSNS1 connector on the controller board
for proper connection.
Is the cable properly connected?
Go to step 5. Go to step 4.
Step 4
Reconnect the cable.
Does the problem remain?
Go to step 5. The problem is
solved.
Step 5
Check the error that appeared.
Is the error 100.42 or 100.43?
Go to step 6. Go to step 10.
Step 6
Check the sensor cables in the isolation unit for proper connection.
Are the cables properly connected?
Go to step 8. Go to step 7.
Step 7
Reconnect the cables.
Does the problem remain?
Go to step 8. The problem is
solved.