 UMX-TPS-TX100 series – User's Manual 89
Stopbits Setting
Command and Response
Î <port>.StopBits=<stopbits>
Í <port>.StopBits=<stopbits>
Parameters
 Parameter description Value Parameter value
<stopbits> Stopbits value
0 1
1 1,5
2 2
Example
Î 
Í 
Parity Setting
Command and Response
Î <port>.Parity=<parity>
Í <port>.Parity=<parity>
Parameters
 Parameter description Value Parameter value
<parity> Parity setting
0 None
1 Odd
2 Even
Example
Î 
Í 
RS-232 Operation Mode
Command and Response
Î <port>.Rs232Mode=<mode>
Í <port>.Rs232Mode=<mode>
Parameters
 Parameter description Value Parameter value
<stopbits> Stopbits value
0 Pass-through
1 Control
2 Command injection
Example
Î 
Í 
INFO: See more information about RS-232 modes in the Technical Background section.
Command Injection Enable
Command and Response
Î <port>.CommandInjectionEnable=<logical_value>
Í <port>.CommandInjectionEnable=<logical_value>
Parameters
 Parameter description Value Parameter value
<logical_value>
Command injection

true Command injection is enabled.
false Command injection is disabled.
Example
Î 
Í 
INFO: The Command injection status is stored in another read-only property:
<serial_port>.CommandInjectionStatus.